Technical Data
Nominal capacity
PS Series Phase separator
Nominal capacity = 16L to 100L
Pressure: Temperature: - -13°F to +392°F (-25°C to +200°C)
Design Codes:- ASME VIII Div. 1 with U-Stamp
- CRN and SQL as required.
- Also available: CE stamp/PED 97/23/EC module G cat.IV VSR/AD-Merkblätter
General Description
- Vertical or horizontal designs
- Both heads flanged or bottom head welded and top cover flanged
- Sight and light glass and lamp.
- PTFE dip-pipe for phase separation.
- Special designs upon request
- Optional vertical strip sight glass
Glass-Lining:- Vessel G2208 dark blue, light-blue or white
- Sigma glass anti-static electrically conductive glass in blue
- Phi glass thermally conductive glass in medium blue
More specific data can also be obtained from our laboratory.
Glass-Lining Controls as per DIN 28063:- Visual inspection
- Thickness testing
- Statiflux (electrified particle test)
- Spark test to ISO 2746 for vessels and accessories at up to 30.000V after glass-lining and again at 12.000V prior to shipment